SPX-5000_MAN_082112SPX-5000 SeriesSuprex® Reader Extender - RF Wireless InterfaceOperations ManualSPX-56012.4GHzSPX-5521900 MhzRPT-56512.4GHz Re
Cypress Suprex RF Series - Door Strike and LED I/OTo activate the relay on the Remote unit, connect as shown below. These connections can be used to
Cypress Suprex RF Series - Door Strike and LED I/OThe Cypress SPX-5000 provides additional data channels to support access control hardware such as do
Relay 3 functions as an Alarm relay and monitors the condition of the communication link between the Central and Remote units. Relay 3 is activated w
Door N.C. ContactRex N.O. Contact1K1KRelay 2 N.O.Relay 2 ComRelay 2 N.C.Relay 1 N.O.Relay 1 ComRelay 1 N.C.Ground Aux inNot usedNot usedexp (+)exp (-)
Before using EXP-2000 Expansion modules with the SPX-5000 system, it will be necessary to perform a short configuration process. This process determin
Door / Parking Gate - TypicalCypress SuprexWireless Solutionwith Wiegand expansion modulesWiegand DataRS-485 Link - Multi-dropCard ReaderControl and I
*Cypress Suprex Series - Wiegand Expansion ModulePanel “Central” interfaceEXP-2000Central Unit8 to 16 VDC InGround485(+)485(-)+5 VDC OutProg Res 4Pro
*EXP-2000Remote Unit8 to 16 VDC InGroundRLY2 N.O.RLY2 ComRLY2 N.C.RLY1 N.O.RLY1 ComRLY1 N.C.RS232 OutRS232 InGroundAux InN/CN/C485(+)485(-)+5 VDC OutR
This manual covers the operation and setup of the Cypress Suprex RF SPX-5000 series wireless units. Overview:The SPX-5000 series of RF Wireless solut
SPX-5521915 Mhz - extender 10000 ft rangeWiegand or Clock & Data816684003387RPT-5551915 Mhz - repeater 1000 ft rangeN/A816684003394SPX-56012.4GHz
External connections and DIP Switch Settings Switch 6 7 8 0 1 x2 x 3 x x 4 x 5 x x 6 x x 7 x x x WiegandWieg
SPX-5000 Series CentralQuick Reference For Typical ConnectionsDCPower SupplyAccessControl Panel+8 to +16 VDCGroundDiagnostic LEDR1 Input Controls Stri
Typical RF installation with repeaterTypical RF installation - line of sightSPX-5000C (1) RPT-5X51ACSSPX-5000C (1)SPX-5000R (1)EXP-2000R (3)EXP-2000R
Quick Reference For Typical ConnectionsSPX-6000 Series CentralAccessControl PanelTXDRXDDCPower SupplyDiagnostic LED+ 5VDCIN 2NOT USEDN.C.COMN.O.Ground
Unpacking:Remove covers from units and check interior for any shipping damage. Remove any packing material if present.Inventory any included parts (d
LED Diagnostic Indicator:The LED Diagnostic indicator provides information on the operational status of the unit.If the units are not communicating, v