Cypress EXP-2000 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
8
10
12
14
16
80
55
35
-40
Ambient Temperature
(Degrees Celsius)
Supply Voltage
Temperature/Voltage de-rating curve
Electrical and Environmental Specifications
The EXP units should be operated with a filtered 12 Volt nominal DC supply. "
Any voltage between 8 and 16 volts can be utilized by following the temperature /voltage derating
curve. Voltage should not exceed 16 VDC under normal operating conditions. "