Cypress NoBL CY7C1471V25 User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
CY7C1471V25
CY7C1473V25
CY7C1475V25
Document #: 38-05287 Rev. *I Page 17 of 32
1.8V TAP AC Test Conditions
Input pulse levels .....................................0.2V to V
DDQ
– 0.2
Input rise and fall time..................................................... 1 ns
Input timing reference levels ...........................................0.9V
Output reference levels...................................................0.9V
Test load termination supply voltage...............................0.9V
2.5V TAP AC Test Conditions
Input pulse levels.................................................V
SS
to 2.5V
Input rise and fall time .....................................................1 ns
Input timing reference levels......................................... 1.25V
Output reference levels ................................................ 1.25V
Test load termination supply voltage ............................ 1.25V
1.8V TAP AC Output Load Equivalent
TDO
0.9V
20pF
Z = 50
O
50
2.5V TAP AC Output Load Equivalent
TDO
1.25V
20pF
Z = 50
O
50
TAP DC Electrical Characteristics And Operating Conditions
(0°C < T
A
< +70°C; V
DD
= 2.375 to 2.625 unless otherwise noted)
[12]
Parameter Description Test Conditions Min. Max. Unit
V
OH1
Output HIGH Voltage I
OH
= –1.0 mA, V
DDQ
= 2.5V 2.0 V
V
OH2
Output HIGH Voltage I
OH
= –100 µA V
DDQ
= 2.5V 2.1 V
V
DDQ
= 1.8V 1.6 V
V
OL1
Output LOW Voltage I
OL
= 1.0 mA V
DDQ
= 2.5V 0.4 V
V
OL2
Output LOW Voltage I
OL
= 100 µA V
DDQ
= 2.5V 0.2 V
V
DDQ
= 1.8V 0.2 V
V
IH
Input HIGH Voltage V
DDQ
= 2.5V 1.7 V
DD
+ 0.3 V
V
DDQ
= 1.8V 1.26 V
DD
+ 0.3 V
V
IL
Input LOW Voltage V
DDQ
= 2.5V –0.3 0.7 V
V
DDQ
= 1.8V –0.3 0.36 V
I
X
Input Load Current GND < V
IN
< V
DDQ
–5 5 µA
Identification Register Definitions
Instruction Field
CY7C1471V25
(2MX36)
CY7C1473V25
(4MX18)
CY7C1475V25
(1MX72)
Description
Revision Number (31:29) 000 000 000 Describes the version number
Device Depth (28:24) 01011 01011 01011 Reserved for internal use
Architecture/Memory Type(23:18) 001001 001001 001001 Defines memory type and architecture
Bus Width/Density(17:12) 100100 010100 110100 Defines width and density
Cypress JEDEC ID Code (11:1) 00000110100 00000110100 00000110100 Allows unique identification of SRAM
vendor
ID Register Presence Indicator (0) 1 1 1 Indicates the presence of an ID
register
Note
12. All voltages refer to V
SS
(GND).