Document #: 38-05556 Rev. *F Page 14 of 29
TAP AC Switching Characteristics Over the Operating Range
[10, 11]
Parameter Description Min Max Unit
Clock
t
TCYC
TCK Clock Cycle Time 50 ns
t
TF
TCK Clock Frequency 20 MHz
t
TH
TCK Clock HIGH time 20 ns
t
TL
TCK Clock LOW time 20 ns
Output Times
t
TDOV
TCK Clock LOW to TDO Valid 10 ns
t
TDOX
TCK Clock LOW to TDO Invalid 0 ns
Setup Times
t
TMSS
TMS Setup to TCK Clock Rise 5 ns
t
TDIS
TDI Setup to TCK Clock Rise 5 ns
t
CS
Capture Setup to TCK Rise 5 ns
Hold Times
t
TMSH
TMS Hold after TCK Clock Rise 5 ns
t
TDIH
TDI Hold after Clock Rise 5 ns
t
CH
Capture Hold after Clock Rise 5 ns
Notes:
10. t
CS
and t
CH
refer to the setup and hold time requirements of latching data from the boundary scan register.
11. Test conditions are specified using the load in TAP AC test Conditions. t
R
/t
F
= 1 ns.